OXIN-F-3

OXIN-F-3®

(Vital Signs Pulse Oximeter)

OXIN-F-3® can be applied in the hospital’s operation room ICU clinic section office
Out-patient department sickroom and emergency treatment.

Category:
Related Accessories
Standard
  • SpO2 Cable (Adult) … 1Pcs
  • NIBP Cuff (Adult) … 1Pcs
  • NIBP Tube(150cm) … 1Pcs
  • Temp sensor … 1pcs
  • Power Adapter … 1Pcs
  • Cleaning Cloth … 1Pcs
Options
  • Cable Sp02 (Adult
  • Soft Sensor the shell)
  • SpO2 Cable ( Adult Soft Sensor the shell)
  • Sp02 Cable (Neonatal Soft Sensor)
  • SpO2 Cable (Pediatric hard shell sensor)
  • SpO2 Cable (Pediatric Soft shell sensor)
  • SpO2 Cable (Child finger clip)
  • SpO2 Cable (multi-site Y type)
  • SpO2 External Cable
  • NIBP Cuff (infant 8 – 14 cm 5/Bag)
  • NIBP Cuff (Child 13 – 20 cm 5/Bag)
  • NIBP Cuff (Small Adult 18 – 26 cm 5/Bag)
  • NIBP Cuff (Adult 26 – 35 cm 5/Bag)
  • NIBP Cuff (Adult Long 29 – 38 cm 5/Bag)
  • NIBP Cuff (Large Adult 32 – 42 cm 5/Bag)
  • NIBP Cuff (Large Adult Long 35 – 44 cm 5/Bag)
  • NIBP Cuff (Thigh 42 – 50 cm)
  • NIBP Tube 150cm
Product Specifications
NIBP
  • Measurement method: Oscillometric
  • Range: Adult: 30mmHg~255mmHg
  • Pediatric: 30mmHg~160mmHg
  • Unit of measurement: MmHg/kPa selectable
  • Measurement mode: Manual Auto STAT
  • Type of measurement: SYS DIA MAP
  • Measuring interval in AUTO mode: 1 2 3 5 10 15 20 30 45 60min
  • Measuring time in mode STAT: 5 min
  • Resolution: 1mmHg
  • Overpressure protection: Adult: 300mmHg Pediatric: 220mmHg
SpO2
  • Range: 0 -100%
  • Resolution: 1%
  • Accuracy: 2% (90~99%) 3% (70~89%) unspecified (< 70%)
PR
  • Range: 30bpm~250bpm
  • Resolution: 1bpm
  • Accuracy: 2bpm
Temperature
  • Channel 2
  • Measuring and alarm range 0 ~ 50 °C
  • Resolution 0,1°C
  • Accuracy ±0,1°C
  • Update interval approx. 1 sec.
  • Average time constant < 10 sec.
Power requirements
  • AC power adapter
  • Input: AC 100~240V 50/60Hz 0.7A
  • Output: 5V 2.5A
  • Internal battery
  • Type: 2.8A built-in Li-ion battery
  • Operating time: 6 hours stand-by time when battery is full.
  • Recharge time: 8 hours
  • Dimensions of the device: 210mm × 188mm × 107mm
  • Net weight: 1000g
Product Features
  • Efficient performance
  • Easy to use
  • Four parameters: NIBP. SpO2, PR, TEMP
  • Suitable for adults, pediatricians and newborns
  • Battery capacity display and low battery warning message
  • Large screen: SpO2 PR is displayed on the screen LED
  • Plethys waveform is displayed on the 2.8 inch color screen in real time
  • 24 hours or AC and built in rechargeable
  • Li-ion battery with up to 6 hours of operating time
  • Storage/viewing of trend data up to 3888 group data storage time interval adjustable
  • Automatic shutdown for energy saving Shutdown time interval adjustable
  • Acoustic and optical alarm when parameters are exceeded and sensor is switched off

Option:

  • Thermal Printer