Standard
- ECG Cable (5 Leads) … 1Pcs
- SpO2 Cable (Adult) … 1Pcs
- TEMP Probe (Adult) … 1Pcs
- NIBP Cuff (Adult) … 1Pcs
- NIBP Tube(150cm) … 1Pcs
- Wall mount with basket … 1pcs
- Remote control … 1pcs
- Ground Cable … 1Pcs
- Power Cable … 1Pcs
- Cleaning Cloth … 1Pcs
Options
- ECG Cable (3 Leads)
- ECG Alligator Clips (Metal)
- SpO2 Cable (Adult hard shell sensor)
- SpO2 Cable (Adult Soft shell sensor)
- SpO2 Cable (Neonatal soft sensor)
- SpO2 Cable (Pediatric hard shell sensor)
- SpO2 Cable (Pediatric Soft shell sensor)
- SpO2 Cable (Child finger clip)
- SpO2 Cable (multi-site Y type)
- SpO2 External Cable
- NIBP Cuff (infant 8 – 14 cm 5/Bag)
- NIBP Cuff (Child 13 – 20 cm 5/Bag)
- NIBP Cuff (Small Adult 18 – 26 cm 5/Bag)
- NIBP Cuff (Adult 26 – 35 cm 5/Bag)
- NIBP Cuff (Adult Long 29 – 38 cm 5/Bag)
- NIBP Cuff (Large Adult 32 – 42 cm 5/Bag)
- NIBP Cuff (Large Adult Long 35 – 44 cm 5/Bag)
- NIBP Cuff (Thigh 42 – 50 cm)
- NIBP Tube 150cm
- Paper Role
- Thermal printer
- Patient Monitor Wall mounts (3 Models)
- Patient Monitor Trolley (5 Models)
- EtCO2 Module
- CO2 Sample Line
- Nasal Tube
- Water-trap Column
- Airway Adapter
- IBP Adapter (2-IBP)
- IBP Reusable Interface Cable
- IBP Disposable Transducers
ECG
- Input mode Five-lead ECG input / three-lead ECG input
- Lead selection I, II, III, aVR, aVL, aVF, V-
- Gain selection AUTO,0.25X,0.5X,1X,2X,4X
- Operating mode Diagnostic mode, monitoring mode, operation modexa0Calibration signal 1mV ±5%
- Protection The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference ofxa0electric knife. Anti-defibrillation protection.
- Pacemaker at the same time use Support
- Electrode off instructions Each electrode (RL excluded)
- Scanning speed 12.5mm/s, 25 mm/s, 50 mm/s
- Common mode rejection ratio ≥90dB
- Input impedance ≥5.0MΩ
Heartrate (HR)
- Measuring range Adult 30 ~ 300bpm, newborns 30 to 350 bpmxa0Resolution 1 bpmxa0Accuracy < ±5bpm
- Heart rate sensitivity ≥0.20mVp-p
- Alarm range 15 to 350 bpm, upper and lower limits
- Alarm indication Audible and visual alarm, display the data and parameters flashing displayxa0alarm
- message text prompts, there are three levels of alarm
Pulse Oximetry
- SPO2 Range: 1% to 99%
- Resolution: 1%
- Accuracy: 70% to 99% range: ±2%;
- 1% to 69% range: ±5%;
- Method: Dual wavelength LED
ST-segment
- ST-segment measurement range -2.0~+2.0mV
- ST-segment measurement accuracy Within the range of -0.8 ~ +0.8 mV: ± 0.02mV orxa0reading± 10%,
- Whichever is greater; Other range: undefined
- Resolution 0.01mV
- ST-segment update cycle 10s
- ST segment alarm range -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable
Arrhythmia analysis
- Arrhythmia types 13 kinds of (scalable)
Respiration Rate
- Rate: 2 to 120 bpm (CO2)
- Resolution: 1 breath/min
NIBP (Non-invasive Blood Pressure)
- Technique: Oscillometric during inflation
- Range: Adult/Pediatric: 40 to 240 mmHg
- Neonate: 10 to 150 mmHg
- Measurement Cycle: < 40 sec. typical
- Automatic Measurement
- Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
- STAT Mode: 5 minutes of continuous readings
- Max. Allowable Cuff
- Pressure: Adult: 300mmHg
- Pediatric: 240 mmHg
- Neonate: 150 mmHg
- Resolution: 1 mmHg
- Transducer Accuracy: ±2 mmHg or ±2% of reading
- Heart (Pulse) Rate
- Range: 30 to 250 bpm
- Accuracy: ±2 bpm or ±3%, whichever is greater
EtCO2 technological index
- Interface form External interface
- Range ofxa0measurement 0~10 kPa or (0~75) mmHg
- precision(error) (0kPa~5.4kPa) the error is ±0.3kPa、(5.5kPa~10.0kPa)the error is ±0.7kPa
- Alarm upper limit 2.1~13.2 kPa
- Alarm lower limit 0~6.5 kPa
- time 12s
- EtCO2 exist
- Unit kPa / mmHg / %
- Compatibilityxa0external main stream and side stream are compatible
IBP technological index
- Measured channel Single way and double way are optional Range of
- measurement SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg)
- MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg)
- DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg)
- Mean error ≤±0.4kPa (±3mmHg)
- MEAN: upper limit 0.3kPa~53.3kPa (2mmHg~400mmHg)
- Lower limit 0kPa~53.1kPa (0mmHg~398mmHg)
- Measured unit mmHg/kPa
- Specification of
- sensor DPT-248(space)
Range of alarm SYS:
- Upper limit 0.3kPa~53.3kPa(2mmHg~400mmHg)
- Lower limit 0kPa~53.1kPa(0mmHg~398mmHg)
DIA:
- Upper limit 0.3kPa~53.3kPa ( 2mmHg~400mmHg)
- Lower limit 0kPa~53.1kPa ( 0mmHg~398mmHg)
- Consumables mode SCW-UTAH-01
- Color display with a resolution of 15 inch
- Touch screen operation more efficient and convenient
- Operation via remote control
- Comply with the YY0709 the alarm system eye catching sub column independent
- Warning lights can be three sound and light alarm immediately
- Pacing analysis can be used simultaneously with pacemakers defibrillators
- 192 hours trend graph waveform freeze 1000 group of blood pressure list
- ST segment measurements arrhythmia analysis
- Various types of multi-line ECG capital letters respiration oxygen content short trend
- Display interface
- Multi-level alarm function to adjust pulse volume; parameter display colors can bexa0customized according to user preference
- User information management functions for patient information entry and identityxa0management
- External replaceable lithium battery for 120 minutes of continuous operation
- External recorder can print the recorded waveform data and other information in real time
- Drug concentration setting and recording for titration calculations to support eventxa0functions
- Up to 32 TCP/IP network connections, consisting of a central information systemxa0Wireless network
Options:
- BP, EtCO2 and Thermal printer
- DC power supply and adaptation to a wide range of environmental conditions
- External recorder can print the recorded waveform data and other information in real time
- External EtCO2 interface can be connected to the CO2 module to meet clinical requirements
- Adjustment and recording of drug concentration in titration calculations to support event
- Up to 32 TCP/IP network connections to form a centralised information system
- Wireless networking
- Invasive blood pressure (IBP)
- Carbon dioxide (CO2) module
- Massimo SpO2 Module
- Thermal printer
- Built-in WIFI
Inquiry
Enter your request in the form
Reviews
There are no reviews yet.