HANIS-A-15

HANIS-A-15

(Touch Screen Patient Monitor)

15 Inch Touch Screen Patient Monitor
192-hour trend graph, 1000 blood pressure groups, ST segment measurements, arrhythmia analysis and other features,
Supports up to 32 TCP/IP network connections, consisting of a central information system.
Comes with remote control

Category:
Related Accessories
Standard
  • ECG Cable (5 Leads) … 1Pcs
  • SpO2 Cable (Adult) … 1Pcs
  • TEMP Probe (Adult) … 1Pcs
  • NIBP Cuff (Adult) … 1Pcs
  • NIBP Tube(150cm) … 1Pcs
  • Wall mount with basket … 1pcs
  • Remote control … 1pcs
  • Ground Cable … 1Pcs
  • Power Cable … 1Pcs
  • Cleaning Cloth … 1Pcs
Options
  • ECG Cable (3 Leads)
  • ECG Alligator Clips (Metal)
  • SpO2 Cable (Adult hard shell sensor)
  • SpO2 Cable (Adult Soft shell sensor)
  • SpO2 Cable (Neonatal soft sensor)
  • SpO2 Cable (Pediatric hard shell sensor)
  • SpO2 Cable (Pediatric Soft shell sensor)
  • SpO2 Cable (Child finger clip)
  • SpO2 Cable (multi-site Y type)
  • SpO2 External Cable
  • NIBP Cuff (infant 8 – 14 cm 5/Bag)
  • NIBP Cuff (Child 13 – 20 cm 5/Bag)
  • NIBP Cuff (Small Adult 18 – 26 cm 5/Bag)
  • NIBP Cuff (Adult 26 – 35 cm 5/Bag)
  • NIBP Cuff (Adult Long 29 – 38 cm 5/Bag)
  • NIBP Cuff (Large Adult 32 – 42 cm 5/Bag)
  • NIBP Cuff (Large Adult Long 35 – 44 cm 5/Bag)
  • NIBP Cuff (Thigh 42 – 50 cm)
  • NIBP Tube 150cm
  • Paper Role
  • Thermal printer
  • Patient Monitor Wall mounts (3 Models)
  • Patient Monitor Trolley (5 Models)
  • EtCO2 Module
  • CO2 Sample Line
  • Nasal Tube
  • Water-trap Column
  • Airway Adapter
  • IBP Adapter (2-IBP)
  • IBP Reusable Interface Cable
  • IBP Disposable Transducers
Product Specifications
ECG
  • Input mode Five-lead ECG input / three-lead ECG input
  • Lead selection I, II, III, aVR, aVL, aVF, V-
  • Gain selection AUTO,0.25X,0.5X,1X,2X,4X
  • Operating mode Diagnostic mode, monitoring mode, operation mode Calibration signal 1mV ±5%
  • Protection The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife. Anti-defibrillation protection.
  • Pacemaker at the same time use Support
  • Electrode off instructions Each electrode (RL excluded)
  • Scanning speed 12.5mm/s, 25 mm/s, 50 mm/s
  • Common mode rejection ratio ≥90dB
  • Input impedance ≥5.0MΩ
Heartrate (HR)
  • Measuring range Adult 30 ~ 300bpm, newborns 30 to 350 bpm Resolution 1 bpm Accuracy < ±5bpm
  • Heart rate sensitivity ≥0.20mVp-p
  • Alarm range 15 to 350 bpm, upper and lower limits
  • Alarm indication Audible and visual alarm, display the data and parameters flashing display alarm
  • message text prompts, there are three levels of alarm
Pulse Oximetry
  • SPO2 Range: 1% to 99%
  • Resolution: 1%
  • Accuracy: 70% to 99% range: ±2%;
  • 1% to 69% range: ±5%;
  • Method: Dual wavelength LED
ST-segment
  • ST-segment measurement range -2.0~+2.0mV
  • ST-segment measurement accuracy Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%,
  • Whichever is greater; Other range: undefined
  • Resolution 0.01mV
  • ST-segment update cycle 10s
  • ST segment alarm range -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable
Arrhythmia analysis
  • Arrhythmia types 13 kinds of (scalable)
Respiration Rate
  • Rate: 2 to 120 bpm (CO2)
  • Resolution: 1 breath/min
NIBP (Non-invasive Blood Pressure)
  • Technique: Oscillometric during inflation
  • Range: Adult/Pediatric: 40 to 240 mmHg
  • Neonate: 10 to 150 mmHg
  • Measurement Cycle: < 40 sec. typical
  • Automatic Measurement
  • Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
  • STAT Mode: 5 minutes of continuous readings
  • Max. Allowable Cuff
  • Pressure: Adult: 300mmHg
  • Pediatric: 240 mmHg
  • Neonate: 150 mmHg
  • Resolution: 1 mmHg
  • Transducer Accuracy: ±2 mmHg or ±2% of reading
  • Heart (Pulse) Rate
  • Range: 30 to 250 bpm
  • Accuracy: ±2 bpm or ±3%, whichever is greater
EtCO2 technological index
  • Interface form External interface
  • Range of measurement 0~10 kPa or (0~75) mmHg
  • precision(error) (0kPa~5.4kPa) the error is ±0.3kPa、(5.5kPa~10.0kPa)the error is ±0.7kPa
  • Alarm upper limit 2.1~13.2 kPa
  • Alarm lower limit 0~6.5 kPa
  • time 12s
  • EtCO2 exist
  • Unit kPa / mmHg / %
  • Compatibility external main stream and side stream are compatible
IBP technological index
  • Measured channel Single way and double way are optional Range of
  • measurement SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg)
  • MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg)
  • DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg)
  • Mean error ≤±0.4kPa (±3mmHg)
  • MEAN: upper limit 0.3kPa~53.3kPa (2mmHg~400mmHg)
  • Lower limit 0kPa~53.1kPa (0mmHg~398mmHg)
  • Measured unit mmHg/kPa
  • Specification of
  • sensor DPT-248(space)

Range of alarm SYS:

  • Upper limit 0.3kPa~53.3kPa(2mmHg~400mmHg)
  • Lower limit 0kPa~53.1kPa(0mmHg~398mmHg)

DIA:

  • Upper limit 0.3kPa~53.3kPa ( 2mmHg~400mmHg)
  • Lower limit 0kPa~53.1kPa ( 0mmHg~398mmHg)
  • Consumables mode SCW-UTAH-01
Product Features
  • Color display with a resolution of 15 inch
  • Touch screen operation more efficient and convenient
  • Operation via remote control
  • Comply with the YY0709 the alarm system eye catching sub column independent
  • Warning lights can be three sound and light alarm immediately
  • Pacing analysis can be used simultaneously with pacemakers defibrillators
  • 192 hours trend graph waveform freeze 1000 group of blood pressure list
  • ST segment measurements arrhythmia analysis
  • Various types of multi-line ECG capital letters respiration oxygen content short trend
  • Display interface
  • Multi-level alarm function to adjust pulse volume; parameter display colors can be customized according to user preference
  • User information management functions for patient information entry and identity management
  • External replaceable lithium battery for 120 minutes of continuous operation
  • External recorder can print the recorded waveform data and other information in real time
  • Drug concentration setting and recording for titration calculations to support event functions
  • Up to 32 TCP/IP network connections, consisting of a central information system Wireless network

Options:

  • BP, EtCO2 and Thermal printer
  • DC power supply and adaptation to a wide range of environmental conditions
  • External recorder can print the recorded waveform data and other information in real time
  • External EtCO2 interface can be connected to the CO2 module to meet clinical requirements
  • Adjustment and recording of drug concentration in titration calculations to support event
  • Up to 32 TCP/IP network connections to form a centralised information system
  • Wireless networking
  • Invasive blood pressure (IBP)
  • Carbon dioxide (CO2) module
  • Massimo SpO2 Module
  • Thermal printer
  • Built-in WIFI

Inquiry

Enter your request in the form

Reviews

There are no reviews yet.

Be the first to review “HANIS-A-15”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “HANIS-A-15”

Your email address will not be published. Required fields are marked *