- ECG Cable (5 Leads) … 1Pcs
- AED Pad Adapter … 1Pcs
- AED Pad … 1pcs
- Ground Cable … 1Pcs
- Power Cable … 1Pcs
- Thermal Paper Role … 1Pcs
- Cleaning Cloth … 1Pcs
- AED Pad for Child
- ECG Cable (3 Leads)
- ECG Alligator Clips (Metal)
- SpO2 Cable (Adult hard shell sensor)
- SpO2 Cable (Adult Soft shell sensor)
- SpO2 Cable (Neonatal soft sensor)
- SpO2 Cable (Pediatric hard shell sensor)
- SpO2 Cable (Pediatric Soft shell sensor)
- SpO2 Cable (Child finger clip)
- SpO2 Cable (multi-site Y type)
- SpO2 External Cable
- NIBP Cuff (infant 8 – 14 cm 5/Bag)
- NIBP Cuff (Child 13 – 20 cm 5/Bag)
- NIBP Cuff (Small Adult 18 – 26 cm 5/Bag)
- NIBP Cuff (Adult 26 – 35 cm 5/Bag)
- NIBP Cuff (Adult Long 29 – 38 cm 5/Bag)
- NIBP Cuff (Large Adult 32 – 42 cm 5/Bag)
- NIBP Cuff (Large Adult Long 35 – 44 cm 5/Bag)
- NIBP Cuff (Thigh 42 – 50 cm)
- NIBP Tube 150cm
- Paper Role
- Defibrillator Wall mounts (3 Models)
- Defibrillator Trolley (5 Models)
- Defibrillator Case
- EtCO2 Module
- IrDA USB Adapter for ECG Data transfer
- CD Software for ECG Data transfer
The ARIO® Xpress is no longer automatically set to a specific frequency response. There are two diagnostic frequency options: 0.05-150 Hz
Diagnostic frequency filter and 0.05-40 Hz filtered diagnostic
Frequency filter. See Chapter 7 to switch between these two options.
The tables below detail the waveforms that the ARIO® Xpress delivers when connected to resistive loads of 25, 50, and 100 ohms and set to its maximum output power.
The waveforms are identified by the peak current (Ip) values DEFI XPRESS for two-phase operation: Duration of the first output phase (tphase1) and Duration of the second output phase (tphase2).
The specified values are within 10%.
Waveform: Truncated exponential curve Biphasic
- +/- 10% or 1J (whichever is greater) at 50 ohms
- +/- 15% or 1J (whichever is greater) at 25 to 100 ohms
- External: 2 5 7 10 20 30 50 70 100 150 200 300 360 J.
- < 06 seconds at 200 J (with a Ni- MH 12 volt – MEDITECH battery).
- < 12 seconds @ 360 J (with a Ni- MH 12 volt – MEDITECH battery after 15 dischargesafter15discharges).
- < 15 seconds @ 360 J (without a battery 90% AC mains voltage)
- Charge level indication: Audible and graphic.
- Adult paddle, pediatric adapter and multipurpose hands-free adapter available.
- Synchronizer : Delivers power within 60 msec.
- Disarm: Front panel switch.
- 3-wire 5-core patient cable
- Size: 8 inch
- Type: Color (TFT)
- Display resolution: 800 x 600 pixels.
- Passing speed: 12.5mm/s25mm/s50mm/s
- Lead selection: I II III AVR AVL AVF V.
- Frequency response: (user selectable).
- 0.7 to 20 Hz Operating mode
- 0.3 to 40 Hz Monitoring mode
- 0.05 to 150 Hz Analysis mode
- 0.5 to 30 Hz AED mode
- Common mode rejection: > =60dB
- Heart rate monitor: 20 to 300 BPM.
- Heart rate alarms: user selectable.
- Size: 0.125 0.25 0.5 1 2 4 cm/mv and auto ranging.
- ECG output: 1 V/mv.
- Heart Rate Response to Irregular Rhythm: (AAMI EC13-1992 Section 4.1.2.1.e.)
- Heart Rate SpO2 Alarm:
- Audible:
- 5-pulse 800 tone with a PW of 150 msec, a PRI of 225 msec, and a repeat interval of 10 seconds.
- Visual:
- The heart rate alarm flashes the displayed heart rate at 2 Hz. This indicator is located at the top of the display and is 0.4″ high and 0.28 to 0.840″ wide, depending on the number of digits in the heart rate.
- It is amber, black, white, or the color of the display text.
- Audible:
Audible: triplet tone with 3 pulses and 500 Hz with a PW of 200 msec and a PRI of 310 msec. If the HR alarm is set or the pacemaker is turned on, the line fault tone repeats at a 20 second repetition interval.
Visual: When a line fault occurs, the message “LEAD FAULT” is displayed on the trace along with a dashed line the width of the trace. The text is 0.18″ high and is the color of the display text. The dashed line is 5″ long and has the width of the display. The signal is not modulated.
- Audible: See heart rate alarm
- Visual: Physiological alarms flash the displayed parameter at 2 Hz. The color is amber, white, or the same as the colored text on the display.
- Mute Duration: 90 seconds.
- Method: automatic oscillation
- Working mode: manual/automatic
- Measurement: adult: 10-250mmHg
- Ement: pediatric: 10-200mmHg
- Ement: neonatal: 10-135mmHg
- End-tidal CO2 (EtCO2):
- Safety EtCO2:BF type
- Current consumption 12.0V±0.2V DC
- Current consumption 100mA (typical with pump on) 200mA (extreme condition)
- Operating temperature range 5~50℃
- Shipping/storage temperature range -20~+70℃
- Relative humidity 0-85% (non-condensing)
- Dimensions 96×91×36mm
- CO2 range 0 to 13%(0-98.8mmHg@BTPS)
- CO2 accuracy < 5.0% CO2 (at BTPS) ± 3 mmHg > 5.0% CO2 (at BTPS) < 10% of reading
- Respiratory rate 3~60 BPM
- Measurement accuracy ±1 BPM
- Warm-up time 10 seconds
- Detector response time: 10mS,
- System: depends on implementation, pneumatics and water separation technology
- Flow control 50~250ml/min
- Interface Highly configurable serial digital interface (TTL/RS232)
- Automatic offset calibration time and temperature dependent and as required
- Type: VVI
- Pulse type: rectangular, constant current
- Pulse amplitude: 0 to 180 mA ± 10% or 5 mA (whichever is greater).
- Pacing frequency: Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)
- Multi-Functional Electrode: (MFE) Pads: Multipurpose defibrillation/pacing electrodes
- Pause: pacing pulse rate is reduced by a factor of 4 upon activation
- Refractory period: NC (VVI requirements do not have this specification)
- Pulse width: (20+ 1.5 ms)
- Output protection: Fully defibrillator protected and isolated
- Type: High resolution thermal array.
- Recording: time date ECG lead ECG gain heart rate defibrillation and treatment summary ACLS events.
- High resolution 8-inch TFT color display.
- Energy selection: 2,5,7,10,20,30,50,70,100,150,200,300,360 Joule.
- Defibrillator Device Voice Alarm.
- Charge time: Less than 7 seconds with a new, fully charged battery.
- Energy display: Monitor display shows both selected and delivered energy.
- Charging prompts: Voice and visual prompts.
- Electrode impedance measurement range: 0-250 ohms.
- Manual mode.
- Built-in printer.
- Reusable standard external adult and pediatric paddles (pediatric paddles integrated)
- AED function: Automatic analysis and charging x3 with programmable automatic energy level selection
- Output waveform: Biphasic technology
- Standard Parameter is ECG: I II III AVR AVL AVF V
Options:
- SpO2
- NIBP module
- EtCO2 module
- Pacemaker
- Trolley
- Carrying case