Standard
- EKG Cable (5 Leads) … 1Pcs
- Ground Wire … 1Pcs
- Battery … 2Pcs
- Power cable … 1Pcs
- Fuse … 2Pcs
- Cleaning Cloth … 1Pcs
Options
- ECG Cable (3 Leads)
- ECG Alligator Clips (Metal)
- SpO2 Cable (Adult hard shell sensor)
- SpO2 Cable (Adult Soft shell sensor)
- SpO2 Cable (Neonatal soft sensor)
- SpO2 Cable (Pediatric hard shell sensor)
- SpO2 Cable (Pediatric Soft shell sensor)
- SpO2 Cable (Child finger clip)
- SpO2 Cable (multi-site Y type)
- SpO2 External Cable
- NIBP Cuff (infant 8 – 14 cm 5/Bag)
- NIBP Cuff (Child 13 – 20 cm 5/Bag)
- NIBP Cuff (Small Adult 18 – 26 cm 5/Bag)
- NIBP Cuff (Adult 26 – 35 cm 5/Bag)
- NIBP Cuff (Adult Long 29 – 38 cm 5/Bag)
- NIBP Cuff (Large Adult 32 – 42 cm 5/Bag)
- NIBP Cuff (Large Adult Long 35 – 44 cm 5/Bag)
- NIBP Cuff (Thigh 42 – 50 cm)
- NIBP Tube 150cm
- Paper Role
- Thermal printer
- Defibrillator Wall mounts (3 Models)
- Defibrillator Trolley (5 Models)
- Defibrillator carry bag
Output waveform Biphasic technology
- Energy accuracy < +1%
- Energy Selection 0.3.5.7.10.20.30.50.100.200.300.360 joules (nominal at resistance of 50)
- Charging time Maximum 8 seconds to 360 joules
- Standard adult/pediatric paddles
- Reusable external adult paddles (pediatric paddles integrated)
Power supply requirements
- AC power supply 110V 60 Hz /220V50 Hz
- Vehicle voltage DC 12V
- Internal buffer battery
- Battery type Rechargeable lead-acid battery/lithium battery (optional)
- Charging time: At least 4 hours for a full charge
- Charge the battery during AC power supply operation of the device.
- Charge indicator / Low battery indicator Red LED
- Battery capacity: 100% of battery allows 120 minutes of monitoring and 30 discharges at 360 joules.
Display
- LED Dimensions 7’diagonal (155mm*88mm)
- Type High resolution true color graphic LED
- Resolution 480X234
ECG
- ECG line: I II III AVR AVL AVF V1 V6 GND
- S-T segment analysis: -2.0/2.0mv
- Arrhythmia analysis: yes
- Protection: with stand 4000vAc/50Hz voltage in isolation and work against electrosurgery and defibrillation
Pulse range
- Pulse range: 0-255bpm
- Pulse oximetry (spO2) Options
- Display: SpO2 value pulse histogram waveform pulse
- Range: 0~99% for adult, pediatric and neonatal patients
- Probe: standard finger clip for adult AED mode (option)
- AED function: automatic analysis and charging x3 with programmable automatic energy
- level selection via on-screen prompts and voice prompts.
- Shock capable rhythms: Ventricular fibrillation with amplitude > =200uV Ventricular
- tachycardia with rates > =140bpm and QRS complex wave duration > =140ms.
- Charge control: front panel, press button on paddle.
- Prompts: Voice and visual prompts.
Recorder
- Paper: 50mm thermal paper.
- Speed: 12.5mm/sec. 25mm/sec. 50mm/sec. User selectable delay of 6 seconds.
- Printing method: High resolution thermal print head.
- Print Modes: Manual or automatic, user configurable.
- On/off control: front panel and paddle.
- High resolution 7-inch TFT color display
- Energy selection: 0,3,5,7,10,20,30,50,100,200,300,360 Joule
- Charge time: Maximum 10 seconds to 360J
- Standard adult/pediatric paddles Reusable external adult external paddles
- Manual mode
- Output waveform: Biphasic technology
- Standard Parameter is ECG: I II III AVR AVL AVF V
- Pulse rate: Pulse range: 0-300bpm Pulse accuracy: ±2bpm Thermal printer
NIBP:
- Method: automatic oscillation
- Working mode: manual/automatic
Measurement:
- adult: 10-250mmHg
- pediatric: 10-200mmHg
- neonatal: 10-135mmHg
TEMP:
- measuring range: 20-45
SpO2:
- SpO2 value
- pulse histogram
- Waveform
- Pulse Thermal printer
Options:
- AED
- Trolley
- Carrying case