Standard
- ECG Cable (5 Leads) … 1Pcs
- SpO2 Cable (Adult) … 1Pcs
- TEMP Probe (Adult) … 1Pcs
- NIBP Cuff (Adult) … 1Pcs
- NIBP Tube(150cm) … 1Pcs
- Ground Cable … 1Pcs
- Power Cable … 1Pcs
- Cleaning Cloth … 1Pcs
Options
- xa0ECG Cable (3 Leads)
- ECG Alligator Clips (Metal)
- SpO2 Cable (Adult hard shell sensor)
- SpO2 Cable (Adult Soft shell sensor)
- SpO2 Cable (Neonatal soft sensor)
- SpO2 Cable (Pediatric hard shell sensor)
- SpO2 Cable (Pediatric Soft shell sensor)
- SpO2 Cable (Child finger clip)
- SpO2 Cable (multi-site Y type)
- SpO2 External Cable
- NIBP Cuff (infant 8 – 14 cm 5/Bag)
- NIBP Cuff (Child 13 – 20 cm 5/Bag)
- NIBP Cuff (Small Adult 18 – 26 cm 5/Bag)
- NIBP Cuff (Adult 26 – 35 cm 5/Bag)
- NIBP Cuff (Adult Long 29 – 38 cm 5/Bag)
- NIBP Cuff (Large Adult 32 – 42 cm 5/Bag)
- NIBP Cuff (Large Adult Long 35 – 44 cm 5/Bag)
- NIBP Cuff (Thigh 42 – 50 cm)
- NIBP Tube 150cm
- Paper Role
- Thermal printer
- Patient Monitor Wall mounts (3 Models)
- Patient Monitor Trolley (5 Models)
- EtCO2 Module
- CO2 Sample Line
- Nasal Tube
- Water-trap Column
- Airway Adapter
- IBP Adapter (2-IBP)
- IBP Reusable Interface Cable
- IBP Disposable Transducers
ECG
- Lead mode 5 leads ( R, L, F, N, C or RA, LA, LL, RL, V)
- Lead selection I, II, III, avR, avL, avF, V,
- Waveform 2 ch
- Derivative mode 3 derivatives ( R, L, F or RA, LA, LL)
- Line selection I , II, III,
- Waveform 1 ch
- Gain ´2.5 mm/mV, ´5.0 mm/mV, ´10 mm/mV, ´20 mm/mV
- HR and alarm
CMRR
- xa0Monitoring > 105 dB
- Operation > 105 dB
- Diagnostics > 85 dB
- Electrode offset potential ±300mV
- Leakage current < 10 uA
- Baseline recovery < 3 S after defi.
- ECG signal range ±8 m V ( Vp-p )
- Bandwidth
- Surgery 1 ~ 15 Hz
- Monitoring 0.5 ~ 35 Hz
- Diagnostics 0.05 ~ 100 Hz
- Calibration signal 1 (mV ), accuracy : ±5%
- ST segment monitoring range
- Measurement and alarm -2.0 ~ +2.0 mV
- ARR detection
- Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT > 2, PVC,
- TACHY, BRADY, MISSED BEATS, PNP, PNC
- Alarm available
- Verification available
Range
- Adult 30 ~ 300 bpm
- Neo/Ped 30 ~ 350 bpm
- Accuracy ±1% or ±1bpm, which is very good
- Resolution 1 bpm
- Sensitivity > 200 uV P-P
- Differential input impedance > 5 MΩ
- CMRR
- Monitoring > 105 dB
- Operation > 105 dB
- Diagnostics > 85 dB
- Electrode offset potential ±300mV
- Leakage current < 10 uA
- Baseline recovery < 10 s after defi.
- ECG signal range ±8 mV (Vp-p)
NIBP
- Surgery 1 ~ 15 Hz
- Monitoring 0.5 ~ 35 Hz
- Diagnostics 0.05 ~ 100 Hz
- Calibration signal 1 mV (Vp-p), ±5% accuracy
Bandwidth
- Measuring range 0 ~ 100
- Alarm range 0 ~ 100
- Resolution 1%
- Accuracy 70% ~ 100% ±2
- 0% ~ 69% not specified
- Update interval approx. 1 sec.
- Alarm delay 10 sec.
- Pulse rate
- Measuring and alarm range 0~254bpm
- Resolution 1bpm
- Accuracy ±2bpm
ST segment monitoring range
- Measurement and alarm -2.0 ~ +2.0 mV
ARR detection
- Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT > 2, PVC,
- TACHY, BRADY, MISSED BEATS, PNP, PNC
- Alarm available
- Verification available
- High T-wave suppression 1.2 mV
- Heart rate averaging from the average of the last 6 R-R intervals, without maximum andxa0minimum
- Display update rate 1s
- Heart rate measurement accuracy and response to irregular rhythms:
- Bigeminy ventricular 80bpm
- Bigeminy ventricular alternatively lente 57 or 63bpm
- Bigeminy ventricular alternatively fast 122 or 123bpm
- Systole bidirectional 95 beats per minute
- Response time to heart rate monitor for a change in heart rate of 80 to 120 bpm
- Average 3.7s
- Range 3.2s ~ 4.1s 80 to 40 bpm
- Average 4.7s
NIBP
- Oscillometric
- Mode Manual, Auto, STAT
- Measuring interval in AUTO mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120,240,480,960min
- Measuring time in STAT mode 5 min
- Pulse rate range 40 ~ 240 bpm
- Alarm type SYS, DIA, MEAN
Measuring and alarm range
- Adult mode
- SYS 40 ~ 270 mmHg
- DIA 10 ~ 215 mmHg
- MEDIUM 20 ~ 235 mmHg
- Pediatric mode
- SYS 40 ~ 200 mmHg
- DIA 10 ~ 150 mmHg
- MEDIUM 20 ~ 165 mmHg
- Neonatal mode
- SYS 40 ~ 135 mmHg
- DIA 10 ~ 100 mmHg
- MEDIUM 20 ~ 110 mmHg
Resolution
- Pressure 1mmHg
- Accuracy
- Pressure
- Maximum mean error ±5mmHg
- Maximum standard deviation ±8mmHg
Protection against overpressure
- Adult mode 297±3 mmHg
- Pediatric mode 240±3 mmHg
- Neonatal mode 147±3 mmHg
TEMPERATURE
- Channel 2
- Measuring and alarm range 0 ~ 50 °C
- Resolution 0,1°C
- Accuracy ±0,1°C
- Update interval approx. 1 sec.
- Average time constant < 10 sec.
IBP (optional)
- Channel 2
- Designation ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range:
- ART 0~300mmHg
- PA -6~120mmHg
- CVP/RAP/ LAP /ICP -10~40mmHg
- P1~P2 -10~300mmHg
Pressure sensor
- Sensitivity 5 uV/V/mmHg
- Impedance 300-3000Ω
- Resolution 1mmHg
- Accuracy ±2% or 1mmHg, which is very good
- Update interval about 1 second
Display
Device:
- 12.1 in. Color TFT, manufactured by Sharp Japan
- Messages 7 waveforms Maximum 1 alarm LED (Yellow/Red)
- Screenshot 1 Power LED (Green)
- 1 Battery charge LED (Yellow)
- 3 Sound mode corresponding to the alarm mode
Signal interface
- ECG output BNC
- Amplitude 1 V/mV
- Accuracy < 5 %
- Impedance 50 Ω
- Signal delay < 20 mS
- Recall
- High resolution 12.1-inch TFT color display
- Light weight, compact and portable
- ECG waveforms of the 7-channel display
- Maximum 8 channel waveform synchronous display
- 72 hours trends in graphical and tabular form for all parameters
- 480 alarm events recallable for all parameters
- Standard configuration: 3/5 lead ECG, NIBP, SpO2, RESP, 2-Temp, PR, Printer
- NIBP measurement mode: manual/AUTO/STAT, memory for 4800 NIBP group data
- Suitable for adult, pediatric and neonatal patients
- Data and waveforms can be color customized
- Arrhythmia analysis and S-T segment analysis
- Standard interface, oxygen chart, trend chart, interface with large font and comfortable bedxa0for observation
- Heart rate variability (HRV) analysis function
- Drug concentration calculation and titration table functions
- Connection to central monitoring system via 3G, Wi-Fi or wired mode
- AC/DC, removable rechargeable lithium battery for continuous monitoring
- Anti-high frequency surgical unit, defibrillation safe (special cables are required)xa0Multilingual
- Capacity 150 minutes continuous operation
Options:
- IBP
- EtCO2
- Thermal printer