Standard
- ECG Cable (5 Leads) … 1Pcs
- SpO2 Cable (Adult) … 1Pcs
- TEMP Probe (Adult) … 1Pcs
- NIBP Cuff (Adult) … 1Pcs
- NIBP Tube (150cm) … 1Pcs
- Ground Cable … 1Pcs
- Power Cable … 1Pcs
- Cleaning Cloth … 1Pcs
Options
- xa0ECG Cable (3 Leads)
- ECG Alligator Clips (Metal)
- SpO2 Cable (Adult hard shell sensor)
- SpO2 Cable (Adult Soft shell sensor)
- SpO2 Cable (Neonatal soft sensor)
- SpO2 Cable (Pediatric hard shell sensor)
- SpO2 Cable (Pediatric Soft shell sensor)
- SpO2 Cable (Child finger clip)
- SpO2 Cable (multi-site Y type)
- SpO2 External Cable
- NIBP Cuff (infant 8 – 14 cm 5/Bag)
- NIBP Cuff (Child 13 – 20 cm 5/Bag)
- NIBP Cuff (Small Adult 18 – 26 cm 5/Bag)
- NIBP Cuff (Adult 26 – 35 cm 5/Bag)
- NIBP Cuff (Adult Long 29 – 38 cm 5/Bag)
- NIBP Cuff (Large Adult 32 – 42 cm 5/Bag)
- NIBP Cuff (Large Adult Long 35 – 44 cm 5/Bag)
- NIBP Cuff (Thigh 42 – 50 cm)
- NIBP Tube 150cm
- Paper Role
- Thermal printer
- Patient Monitor Wall mounts (3 Models)
- Patient Monitor Trolley (5 Models)
- EtCO2 Module
- CO2 Sample Line
- Nasal Tube
- Water-trap Column
- Airway Adapter
- IBP Adapter (2-IBP)
- IBP Reusable Interface Cable
- IBP Disposable Transducers
ECG
- Lead mode 5 leads ( R, L, F, N, C or RA, LA, LL, RL, V)
- Lead selection I, II, III, avR, avL, avF, V,
- Waveform 2 ch
- Derivative mode 3 derivatives ( R, L, F or RA, LA, LL)
- Line selection I , II, III,
- Waveform 1 ch
- Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV, auto
- HR and alarm
Range:
- Adult 15 ~ 300 bpm
- Neo/Ped 15 ~ 350 bpm
- Accuracy ± 1% or ± 1 bpm, which is very good
- Resolution 1 bpm
- Sensitivity > 200 (uV)
- Differential input impedance > 5 MΩ
CMRR
- Monitoring > 105 dB
- Operation > 105 dB
- Diagnostics > 85 dB
- Electrode offset potential ±300mV
- Leakage current < 10 uA
- Baseline recovery < 3 S after defi.
- ECG signal range ±8 m V (Vp-p )
Bandwidth:
- Surgery 1 ~ 15 Hz
- Monitoring 0.5 ~ 35 Hz
- Diagnostics 0.05 ~ 100 Hz
- Calibration signal 1 (mV), accuracy : ±5%
- ST segment monitoring range
- Measurement and alarm -2.0 ~ +2.0 mV
- ARR detection
- Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT > 2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
- Alarm available
- Verification available
Respiration
- Method Impedance between RF (RA-LL)
- Differential input impedance > 2.5 MΩ
- Range of measurement impedance: 0.3~5.0Ω
- Base line impedance range: 0 – 2.5 KΩ
- Bandwidth 0.3~2.5 Hz
Response rate:
- Measuring and alarm range
- Adult 0 ~ 120 rpm
- Neo/Ped 0 ~ 150 rpm
- Resolution 1 rpm
- Accuracy ±2 rpm
- Apean alarm 10 ~ 40 S
NIBP
- Method Oscillometric
- Mode Manual, Auto, STAT
- Measuring interval in AUTO mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 (min)
- Measuring time in STAT mode 5 min
- Pulse rate range 40 ~ 240 bpm
- Alarm type SYS, DIA, MEAN
- Measurement and alarm range
Adult mode:
- SYS 40 ~ 270 mmHg
- DIA 10 ~ 215 mmHg
- MEAN 20 ~ 235 mmHg
Pediatric mode:
- SYS 40 ~ 200 mmHg
- DIA 10 ~ 150 mmHg
- MEAN 20 ~ 165 mmHg
Neonatal mode:
- SYS 40 ~ 135 mmHg
- DIA 10 ~ 100 mmHg
- MEAN 20 ~ 110 mmHg
- Resolution
- Pressure 1mmHg
- Accuracy
Pressure:
- Maximum mean deviation ±5mmHg
- Maximum standard deviation ±8mmHg
- Protection against overpressure
- Adult mode 297±3 mmHg
- Pediatric mode 240±3 mmHg
- Neonatal mode 147±3 mmHg
SpO2
- Measuring range 0 ~ 100
- Alarm range 0 ~ 100
- Resolution 1%
- Accuracy 70% ~ 100% ±2xa00% ~ 69% not specified
- Update interval approx. 1 sec.
- Alarm delay 10 sec.
- Pulse rate
- Measuring and alarm range 0~254bpm
- Resolution 1bpm
- Accuracy ±2bpm
Temperature
- Channel 1
Measuring and alarm:
- range 0 ~ 50 C
- Resolution 0,1~C
- Accuracy ±0,1~C
- Update interval approx. 1 sec.
- Average time constant < 10 sec.
IBP Module
- Designation ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range:
- ART 0 ~ 300 mmHg
- PA -6 ~ 120 mmHg
- CVP/RAP/ LAP /ICP -10 ~ 40 mmHg
- P1/P2 -10 ~ 300 mmHg
- Pressure sensor
- Sensitivity 5 uV/V/mmHg
- Impedance 300-3000Ω
- Resolution 1 mmHg
- Accuracy ±2% or ±1mmHg, which is about 1 second
- High resolution 15.1 inch TFT color display
- Standard parameters: ECG, respiration, NIBP, SpO2, TEMP,xa0VGA output for external display
- Maximum 8 channel waveform synchronous display
- Built in rechargeable lithium battery pack
- Three working modes: monitoring, operation and diagnosis
- Data and waveforms color adjustable
- Arrhythmia analysis and S-T segment analysis
- Suitable for adult, pediatric and neonatal patients
- Display 7 channel ECG waveforms on one screen, cascade ECG waveform display
- Built in battery for up to 2 hours of continuous operation
- System software can be upgraded via USB
Options:
- IBP
- EtCO2
- Thermal printer
Inquiry